ReinraumHeizung-9993
XY-Lösung für Firma
Support-3464-2_web-91b85616
Gebaeude-3566-2A_web

Error Code 112

Cause: Voltage signal incorrect, calibration not possible

Measure during initial startup

Fault area 7:

Explanation: UR signal incorrect

Possible causes: Secondary voltage U2 outside of permissible range of 0.4…120 VAC.

check configuration.

Measure during operation, HBAbbreviation HB not changed

Fault area 4:

Explanation: Partial bypass (delta R)

Possible causes: Heating element partially bypassed by conducting part, e.g. clamp, opposite heat-sealing bar

Fault area 5:

Explanation: Parallel circuit interrupted

Possible causes:

  • Wire break, heating element break.
  • Contact to heating element is defective.

Fault area 6:

Explanation: Total bypass

Possible causes:

  • Heating element incorrectly installed, no insulation at heat-sealing bar ends or insulation incorrectly installed
  • Heating element completely bypassed by conducting part.

 Fault areas: