Part 1 of 3: Troubleshooting
The errors are reported as faults.
- The analog output emits constant voltage, the level of which is associated with a set of error codes.
- ALARM LED remains illuminated.
- Alarm relay is active.
Error code | Analog signal voltage [V] | Cause | Measure during initial startup | Measure during operation, HB1) not changed |
|---|---|---|---|---|
101 | 0.66 | Current signal missing |
| |
102 | 1.33 | Voltage signal missing |
| |
103 | 2.00 | Voltage and current signals missing |
|
|
107 | 2.66 | Temperature drop |
| |
108 | Temperature spike | |||
307 | Temperature too low, tolerance band was left |
| ||
308 | Temperature too high, tolerance band was left | |||
309 | Temperature too low, tolerance band was not reached | |||
310 | Temperature too high, tolerance band was not reached | |||
201 | 3.33 | Line frequency missing/fluctuates |
| |
202 | Line frequency too high/fluctuates | |||
203 | Line frequency too low/fluctuates | |||
304 | 4.00 | Heat-up time too long |
|
|
305 | Starting temperature too high |
| ||
901 | 4.66 | Line voltage/synchronizing signal missing |
| |
913 | Triac defective |
| ||
914 915 | Internal error: Comparator in measuring module defective | |||
916 | Internal error: Test mode not ended successfully | |||
917 918 | Slide for alarm output not plausible. |
| ||
919 | Internal error: Comparator in measuring mode not plausible |
| ||
920 |
|
| ||
930 | Internal communication module does not reply when temperature controller is switched on |
| ||
931 | Internal communication module indicates an error when temperature module is switched on | |||
932 | Internal communication module does not reply during operation | |||
933 | Internal communication module indicates an error during operation | |||
934 | Internal communication module does not reply during operation | |||
935 | Communication module firmware is not plausible (does not match device type) |
| ||
937 | Internal communication module not started correctly |
| ||
938 939 940 9412) | Internal error: Capacitor in measuring module defective |
| ||
Heatsealing band
Available beginning with firmware 313